General Information
Emergency Safety Showers and Eye Washes are Essential Safety Devices
- Accidents caused by fire, scalding and others often happen in numerous firms.
- There are also risks of eye injuries at places where great amount of dust can accumulate, for example, wood products production workshops.
- The danger also lurks at schools, in laboratories, large kitchens, ships and at other places.
- Experience shows that thousands of industrial accidents happen every year in spite of strict precautionary measures. These accidents cause the injured acute pain, disablement and may even lead to loss of lives.
- The consequences of such accidents could be consiuderably limited by treating with water immediately.
- Serious personal injury can be avoided through small costs. This is why every place where the danger lurks should install emergency safety showers or eye washes.
Installation and Operation of Emergency Safety Showers
- As a basic rule the emergency safety showers must be placed as close to the working places as possible. The flushing must start immediately after the accidents have occurred, and last at least 5 seconds. When installing the emergency safety showers, please remember that the showers must be easy to find and that the access must always be free.
- If a person works alone, it is wise to install a sound and/or light alarm too, which begins functioning as soon as the shower is operated.
Operation
- All emergency safety showers are constructed in a way that enssures easy operation.
- When activating the emergency shower, the flushing continues automatically.
- The injured person has help to keep eyes open by hand.
- On the eye washes, the nozzles are protected by rubber cups to keep the injured from hurting again.
- The nozzles also protect against dust and dirt by the caps, which are removed automatically by water.
Water Pressure and Temperature
- The emergency safety showers are connected to the cold water system which ensures clean and fresh water. The temperature should be around 8ºC to 20 ºC.
- The eye washes have the different pressure atomizing lip. It can be on the basic of locale hydraulic pressure to use the different pressure atomizing lip for the best effect.
Product Description
Bench-mounted Douhble Eye Wash for Laboratory
Solid Brass Unit
ME-H2155-2
Body: solid brass
Spray head: soft rubber, softened water spray for eye protection
Dust cap: PP, removed automatically when eye wash is operated
Switch: automatic trigger locking for easy hand-free use
Valve: non-return valve, shut off automatically
Hose: length of 1.5m, PVC pipe with stainless steel wire braided, wrapped by PE pipe relief from rust and leakage
Max. working pressure: 7Bar
![Bench-Mounted Solid Brass Single Eyewash](//www.micstatic.com/athena/img/transparent.png)
![Bench-Mounted Solid Brass Single Eyewash](//www.micstatic.com/athena/img/transparent.png)
![Bench-Mounted Solid Brass Single Eyewash](//www.micstatic.com/athena/img/transparent.png)
Packaging & Shipping
Bench removable eye wash(2155-4)
Packing list
Please count the number of parts out of the box in the following list, check there is no damage on the transport, if you have problems or insufficient quantity, please immediately contact our local distributor or contact the company, you will get a satisfactory answer.
Number |
Fitting name |
Quantity(set) |
1 |
Main Body Part (with control valve) |
One |
2 |
Fixed Pallet Part |
One |
3 |
Supply water Hose |
One |
Operation instructions of bench removable eye wash (2155-4)
Using
Security Eye-washing sprayer is not only the essential equipment of labors protection but also the essential protection facilities against poisonous and corrosive material. If accidents happen, please reduce the hurt to the minimum degree by quickly spraying and washing the hurt with the sprayer.
Product performance characteristic
1. The shell of eye wash is ABS plastic injection molding, handfeel comfortable, ergonomic design.
2. Bench Installation, usually placed on the worktop, when emergency, to draw out optional, use convenient.
3. With self-locking function, the switch is flexible and convenient, meeting the emergency use requirements.
4. The outlet is treated by reducing the diameter, and the water flow is more soft and rich;
- Add filter mat, which can effectively avoid damage to sealing performance caused by impurities in water source;
- The front control valve can better maintain and improve the performance of the product. When repairing the product or cleaning the filter screen, directly turn the front control valve knob clockwise to the closed state, and the operation can be carried out on the platform without closing the valve at the water source. The operation is very convenient. In addition, the water flow of eye washing can be controlled by rotating the knob to make the eye washing water bundle soft under different water pressures, so as to avoid secondary injury to eyes due to high water pressure.
Main technical parameter
Pressure grade (MPa) |
Flux L/min |
Applicable condition |
Normal pressure |
Seal pressure |
Working pressure |
≥6 |
The normal temperature pure water or conforms to the hygienic standard water |
0.4 |
0.45 |
0.20~0.40 |
Installing instruction:
A. Installation Environment
- Before installing, should confirm whether the inlet pipe is installed completely and washing, to ensure that no impurities in the pipe.
2. Inlet water pressure requirement:0.2Mpa<inlet water pressure<0.6Mpa
B. Installation steps
1. Before installation, please make sure have 32 mm diameter hole is drilled.
2. Remove the stable sleeve in the tray, end of lock nut and flat washer etc.
3. Pass the hose through the tray hole with the taper upward;
4. Screw the taper nut of the hose (with rubber gasket inside) onto the 1 2 "thread of the front control valve at the lower end of the eye washer body;
5. Connect the other end of the hose (with rubber gasket inside) with the 1 2 "thread of the water inlet pipe;
6. Place the eye washer body on the tray;
7. Connect the water inlet pipe and check whether the connections are firm and whether there is water leakage;
8. Test: take out the eye washer, press the push button and push it forward, that is, turn on the switch, and check whether the water from the nozzle is smooth and whether there are impurities not removed; Whether the water jet is suitable for eye washing can be adjusted by rotating the front control valve knob. After the test, pull back and release the push button to close the switch.
Instructions for use:
When in use, extract the main body of the eye washer from the tray, press the push button with your thumb and push it forward at the same time, open and close the valve and lock the water flow, and then shower; After showering, pull back the push button and release it to close the valve, and then place the eye washer body on the tray.
Troubleshooting suggestions:
No. |
Fault |
CAUSE |
Remedy |
1 |
Small water flow of nozzles |
a. There is dirt in the water inlet, and the nozzle hole or water inlet pipe is blocked b. The control valve is not adjusted in place
c. Inlet with Low water pressure |
a. Close the control valve, unscrew the main part of the control valve with water, and clean the filter screen b. Turn the control valve knob counterclockwise c. Increase inlet water pressure |
2 |
The outlet flow of the nozzle is large |
The control valve is not adjusted in place |
Turn the control valve knob clockwise |
3 |
Water leakage at hose connection |
The rubber pad at the connecting nut is damaged |
Replace the rubber mat |
Notices:
1. If the water pressure is lower than 0.15 MPa, it may cause the water outlet effect is not so good, and if it is higher than 0.6 MPa, it may cause closing not well.
2. The main body of the eye washer shall not be twisted by force, and the hose shall be bent naturally
![Bench-Mounted Solid Brass Single Eyewash](//www.micstatic.com/athena/img/transparent.png)
Other bench-mounted eye wash
![Bench-Mounted Solid Brass Single Eyewash](//www.micstatic.com/athena/img/transparent.png)
![Bench-Mounted Solid Brass Single Eyewash](//www.micstatic.com/athena/img/transparent.png)
![Bench-Mounted Solid Brass Single Eyewash](//www.micstatic.com/athena/img/transparent.png)
FAQ
Q1. Why choose us?
A1. We are the leading laboratory products supplier, OEM & ODM service are offered.
Q2. What's MAYEN main products?
A2. We supply epoxy resin worktops, epoxy resin sinks, phenolic worktops, water faucets, gas fittings, emergency showers, eye washes, pegboards, extraction arms and other accessories, fume hoods, equipment and lab furniture for laboratory.
Q3. How about the sample?
A3. We could send you the samples but the freight is collect.
Q4. How about the payment term?
A4. T/T & L/C (50% deposit, the balance before shipment).
Q5. How about the delivery time?
A5. Within 7-15 workdays after receiving deposit.
Q6. How about the validity of quotation?
A6. Usually 60 days as the shipping freight and exchange rate can be fluctuant.
Q7. What is the shipping port?
A7. FOB to Guangzhou or Shenzhen Port,China(also can ship according to customers' request).
Q8. How about the package?
A8. Wooden crating or carton.
Q9. How to inspect the goods?
A9. Products will checked by our QC staff first, then our proejct manager. Client can come and check by themselves or by the third party.